Trying to login PIA,
I got below error messages
CHECK APPSERVER LOGS. THE SITE BOOTED WITH INTERNAL DEFAULT SETTINGS, BECAUSE OF: bea.jolt.ServiceException: Invalid Session
or
application server down at this moment.
or
application server down at this moment.
So I looked at the app server log & below error message
So obviously I googled, I got information from below site managed by Nicolas:
So I checked web server configuration.properties for DomainConnectPswd parameter. Found the value its encrypted like {V1.1}qeurng=.
& I checked in app server for the same parameter it has some value ENCRYPT. From Nicolas, he says both places this parameter should be same.
So what i did was manually opened psappsrv.cfg & changed DomainConnectPswd parameter to blank.
& Rebooted the app server. Whoa!! able to connect PIA.. Thanks Nicolas providing wonderful info.